Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Arch. cardiol. Méx ; 93(4): 391-397, Oct.-Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527715

ABSTRACT

Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.

2.
Gac. méd. Méx ; 158(6): 380-386, nov.-dic. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430367

ABSTRACT

Resumen Introducción: Las bioprótesis de válvulas cardiacas son el estándar de oro para el reemplazo quirúrgico de la válvula aórtica en pacientes seleccionados. Objetivo: Evaluar la seguridad y eficacia de la válvula cardiaca bioprotésica del Instituto Nacional de Cardiología (INC) en humanos. Métodos: Estudio unicéntrico que incluyó 341 pacientes que se sometieron a reemplazo valvular quirúrgico único de válvula aórtica con válvula INC. Resultados: Se realizaron 318 implantes de novo (93 %) y 23 como segunda cirugía (7 %); las puntuaciones STS fueron de 1.4 y 1.8 % y el seguimiento de 42 y 46 meses, respectivamente. No existieron diferencias en las complicaciones ni en la tasa de implantación de marcapasos. Ambos grupos mantuvieron una FEVI normal. Se observó mejoría global en la clase funcional con empeoramiento solo en dos pacientes del grupo de novo. La disfunción de la prótesis INC que ameritó reintervención quirúrgica se observó en ocho pacientes (4.65 %) del grupo de novo versus un paciente (7.69 %) con segunda cirugía. Conclusiones: La válvula cardiaca INC es eficaz y segura, se asocia a baja tasa de complicaciones y mejoría de la clase funcional durante el seguimiento a largo plazo. Se necesitan estudios prospectivos comparativos de esta válvula.


Abstract Introduction: Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients. Objective: To evaluate the safety and efficacy of the of the National Institute of Cardiology (INC) bioprosthetic heart alve of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans. Methods: Single-center study that ncluded 341 patients who underwent single surgical aortic valve replacement with INC heart valve. Results: 318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group. Conclusions: The INC heart valve is efficacious and safe, and is associated with a The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.

3.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Article in English | LILACS | ID: biblio-1249911

ABSTRACT

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Subject(s)
Animals , Male , Female , Rabbits , Paclitaxel/administration & dosage , Sirolimus/administration & dosage , Drug-Eluting Stents , Prosthesis Design , Spectrophotometry, Infrared , Swine , Follow-Up Studies , Disease Models, Animal , Microscopy
4.
Arch. cardiol. Méx ; 90(2): 142-147, Apr.-Jun. 2020. graf
Article in English | LILACS | ID: biblio-1131023

ABSTRACT

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Subject(s)
Humans , Animals , Dogs , Rabbits , Prosthesis Design , Stents , Coronary Vessels/surgery , Coronary Artery Disease/surgery , Fluoroscopy , Chromium Alloys/chemistry , Models, Animal
5.
Rev. invest. clín ; 72(1): 32-36, Jan.-Feb. 2020. graf
Article in English | LILACS | ID: biblio-1251832

ABSTRACT

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Subject(s)
Humans , Male , Adult , Middle Aged , Aged , Prosthesis Design , Stents , Myocardial Ischemia/surgery , Pilot Projects , Follow-Up Studies , Ultrasonography , Treatment Outcome , Myocardial Ischemia/physiopathology , Myocardial Ischemia/diagnostic imaging , Mexico
6.
Arch. cardiol. Méx ; 88(2): 83-92, abr.-jun. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-1054998

ABSTRACT

Resumen Antecedentes: El mejor método para el tratamiento de la revascularización de la lesión del tronco no protegido de la coronaria izquierda es un tema de creciente interés. Método: Se realizaron un total de 2,439 intervenciones coronarias percutáneas (ICP) durante 3 años; se incluyeron los pacientes con lesión del tronco no protegido de la coronaria izquierda (TCI; n = 48) y se compararon con pacientes a los que se realizó cirugía de revascularización coronaria (CRVC; n = 50). Se analizaron los eventos cardiovasculares en fase hospitalaria y extrahospitalaria. El promedio de seguimiento fue de 16 meses. Resultados: El riesgo cardiovascular fue mayor en pacientes con ICP; log EuroSCORE (16 ± 21 vs. 5 ± 6, p = 0.001), Syntax clínico (77 ± 74 vs. 53 ± 39, p = 0.04). Los pacientes del grupo de ICP presentaron al ingreso con más frecuencia infarto con elevación del ST (IMCEST) y con choque cardiogénico. Los eventos hospitalarios fueron similares en ICP y CRVC (14% vs. 18%, p = 0.64). El IMCEST fue menos frecuente en el grupo de ICP (0% vs. 10%, p = 0.03. Los eventos cardiovasculares fueron menores en el grupo de ICP (2.3% vs. 18%, p = 0.01) y hubo una disminución de la muerte general y cardiaca (2.3% vs. 12%, p = 0.08 y 2.3% vs. 8%, p = 0.24), al excluir los pacientes con choque cardiogénico como presentación. En la fase extrahospitalaria los eventos fueron similares en ICP y CRVC (15% vs. 12%, p = 0.46). La supervivencia sin eventos cardiovasculares, muerte general y cardiaca fueron comparables entre los grupos (log rank, p = 0.38, p = 0.44 y p = 0.16). Conclusión: Pese a que los pacientes de ICP mostraron un perfil de riesgo mayor que los de CRVC, la seguridad y eficacia intrahospitalaria y extrahospitalaria fueron similares. © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. Este es un artículo Open Access bajo la licencia CC BY-NC-ND (https://creativecommons.org/licenses/by-nc-nd/4.0/).


Abstract Background: The best revascularisation method of the unprotected left main artery is a current and evolving topic. Methods: A total of 2439 percutaneous coronary interventions (PCI) were registered during a 3-year period. The study included all the patients with PCI of the unprotected left main coronary (n = 48) and matched with patients who underwent coronary artery bypass graft (CABG) (n = 50). Major adverse cerebral and cardiac events (MACCE) were assessed within the hospital and in outpatients during a 16 month follow up. Results: The cardiovascular risk was greater in the PCI group; logEuroSCORE 16 ± 21 vs. 5 ± 6, P = .001; clinical Syntax 77 ± 74 vs 53 ± 39, P = .04. On admission, the PCI group of patients had a higher frequency of ST segment elevation myocardial infarction (STEMI) and cardiogenic shock. The MACCE were similar in both groups (14% vs. 18%, P = .64). STEMI was less frequent in the PCI group (0% vs. 10%, P = .03). Cardiovascular events were lower in the PCI group (2.3% vs. 18%, P = .01), and there was a decrease in general and cardiac mortality (2.3% vs. 12%, P = .08 y 2.3% vs. 8%, P = .24), on excluding the patients with cardiogenic shock as a presentation. MACCE were similar in both groups in the out-patient phase (15% vs. 12%, P = .46). Survival without MACCE, general and cardiac death were comparable between groups (log rank, P = .38, P = .44 and P = .16, respectively). Conclusion: Even though the clinical and periprocedural risk profile of the PCI patients were higher, the in-hospital and out-hospital efficacy and safety were comparable with CABG. © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).


Subject(s)
Humans , Male , Female , Aged , Coronary Artery Disease/surgery , Coronary Artery Bypass , Percutaneous Coronary Intervention/methods , Time Factors , Case-Control Studies , Retrospective Studies , Longitudinal Studies , Treatment Outcome , Mexico
7.
Arch. cardiol. Méx ; 88(5): 432-440, dic. 2018. graf
Article in Spanish | LILACS | ID: biblio-1142153

ABSTRACT

Resumen Introducción: Un trombo intracorononario largo reclasificado es un predictor independiente de resultados adversos y no reflujo en el infarto agudo de miocardio con elevación del ST. Pacientes con mayor carga de trombo residual tienen peor disfunción microvascular y mayor daño miocárdico. Métodos: Evaluamos retrospectivamente a 833 pacientes que fueron a angioplastia primaria entre enero del 2011 y junio del 2016. La carga de trombo residual final fue reclasificada tras realizar el cruce de la guía, predilatación con balón o tromboaspiración, para restaurar y estabilizar un flujo TIMI 2-3. Las estrategias de stent diferido vs. stent inmediato fueron comparadas, siendo el objetivo primario la incidencia de no reflujo (TIMI ≤ 2, o TIMI 3 con TMP < 2). Resultados: Cuarenta y siete pacientes (6.8%) presentaron una alta carga trombo residual reclasificado. La coronaria derecha fue la arteria culpable en 34 casos. Hubo mayor frecuencia de ectasia coronaria en el grupo de stent diferido (p = 0.005). Se encontraron menores tasas de no reflujo en el stent diferido (36% vs. 58%), con una mayor frecuencia de un TMP 3 (p = 0.005). Tras la nueva cateterización un 56% quedó libre de stent en el grupo diferido y la anticoagulación oral les fue más frecuentemente indicada (p = 0.031). La tasa de eventos cardiacos adversos mayores fue similar entre los grupos. Hubo una tendencia a una mejor función ventricular izquierda en el grupo diferido (p = 0.056). Conclusiones: El stent diferido puede ser una alternativa eficiente en pacientes con IAM CEST y alta carga de trombo residual reclasificado, después de conseguir un flujo TIMI 2-3 estable.


Abstract Background: Reclassification of a large thrombus burden is an independent predictor of major adverse cardiac events and no-reflow in patients with ST- segment elevation myocardial infarction (STEMI). Patients with a greater residual thrombus burden have worse microvascular dysfunction and greater myocardial damage. Methods: A retrospective analysis was performed on 833 STEMI patients who underwent primary percutaneous coronary intervention. The final residual thrombus burden was reclassified after the lesion was wired, and a thrombus aspiration or balloon dilatation was performed to restore and stabilise a thrombolysis in myocardial infarction (TIMI) 2-3 flow. Deferred stenting (DEI) was compared with immediate stenting (ISI) group, and the primary outcome was the incidence of no-/slow-reflow (TIMI ≤ 2, or TIMI 3 with myocardial blush grade < 2). Results: Overall, 47 patients (6.8%) had a residual large thrombus burden reclassified. The right coronary artery was the culprit vessel in 34 cases. More patients had coronary ectasia in the DSI group (P=.005). Fewer patients in the DSI had no-/slow-reflow (36% vs. 58%), and the myocardial blush grade 3 was more frequent in the DSI group (P=.005). After repeat coronary angiography in the DSI group, stenting was not performed in 56%, and oral anticoagulation was more frequent in the follow-up (P=.031). Major cardiac adverse events were similar between groups. There was a tendency to better left ventricular function in the DSI group (P=.056). Conclusions: Deferred stenting may be an efficient option in STEMI patients with a residual large thrombus burden reclassified after achieving a stable TIMI 2-3 flow.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Coronary Thrombosis/therapy , Stents , Coronary Angiography/methods , Percutaneous Coronary Intervention/methods , ST Elevation Myocardial Infarction/therapy , Time Factors , Coronary Thrombosis/diagnostic imaging , Retrospective Studies , Follow-Up Studies , Longitudinal Studies , Ventricular Function, Left , Anticoagulants/administration & dosage
9.
Arch. cardiol. Méx ; 77(2): 110-119, abr.-jun. 2007. tab
Article in Spanish | LILACS | ID: lil-566703

ABSTRACT

We evaluated immediate and mid-term clinical and angiographic results in diabetic patients with percutaneous coronary intervention with deployment of drug eluting stents. METHODS: Between November of 2004 and June of 2005 percutaneous coronary interventions were performed 860 with the deployment of 112 drug eluting stents to 42 diabetic patients. The mean of stents was 2.6 per patient, and the type of drug eluting stent was paclitaxel in 60% and sirolimus in 40%. The average of age was 51.2 +/- 9.6 years old. The gender was male in 25 (60%) of patients and female in 17 (40%). The indication of coronary angiography was unstable angina in 15 (35%) patients and stable angina in 27 (65%). There was history of anterior myocardial infarction in 20 (47%), inferior myocardial infarction in 8 (20%) and multiple vessel disease in 16 (38%). The stenosis severity of the lesion was 85.9% +/- 12.2% and the left ventricular function was (55 +/- 10). The hospital stay was 7 +/- 5.4 days. RESULTS: Both clinical and angiographic immediate success was 100%. The average follow was 7.6 +/- 3.3 months in 34 patients (80.9%). The target lesion revascularization (TLR) was 7.1%. (3 patients). Death, myocardial infarction or reinfarction (0%). COMPLICATIONS: One patient (2.3%) developed contrast induced nephropathy. CONCLUSIONS: These results suggest that the use of drug eluting stents (paclitaxel or sirolimus) in diabetic patients has a high rate of success with good angiographic and clinical results and with a low rate of complications or restenosis in this high risk group of patients.


Subject(s)
Female , Humans , Male , Coronary Restenosis , Drug Delivery Systems , Stents , Diabetic Angiopathies
10.
Arch. cardiol. Méx ; 76(1): 28-36, ene.-mar. 2006.
Article in Spanish | LILACS | ID: lil-569530

ABSTRACT

Since the last decade, percutaneous balloon mitral valvuloplasty with Inoue catheter is considered the treatment of choice for selected patients (mobile valve, no calcification and minimal subvalvular disease) with rheumatic mitral stenosis. OBJECTIVE: We present the seven-year follow-up experience of 456 patients treated with this technique in the catheter laboratory of the Cardiology Hospital in National Medical Center SXXI. MATERIAL AND METHODS: It is a retrospective, transversal and observational study performed with data obtained from January 1994 and December 2000, with a follow-up of 58.5 +/- 26.6 months (range 12-96 mean 22). RESULTS: We achieve an initial success of 82.8%, improvement of initial mitral valve area from 0.9 +/- 0.1 to 1.8 +/- 0.3 cm2, with a gain area from 88 to 106% (p < or = 0.001). At the end of the follow-up, the mean valvular area was maintained in 1.7 +/- 0.3 cm2 in 69.8% of the cases. We found a significant reduction of transmitral gradient and of the pulmonary artery systolic pressure immediately after the procedure; 93.1% of patients were in NYHA functional class II at the end of the follow-up, 11.6% presented complications (mitral regurgitation as the most important), in 15.9% of them, due to leaflet rupture, but only 9.1% corresponded to severe grade Ill-IV. COMPLICATIONS: Only one patient died due to septal perforation; 93.8% of the patients remained free of major cardiac events at the end of the study. Only 6.1% of the patients required surgery at the end of the follow-up; 5.5% were in functional class NYHA Ill-IV and restenosis occurred in 14.6%. CONCLUSION: Percutaneous balloon mitral valvuloplasty with Inoue balloon catheter is a safe and effective technique for treating rheumatic mitral stenosis with Wilkins score < 10, with minimal risk and complications and offers good life expectancy with absence of major cardiac events in > 90%. From these patients, 93.1% remained in NYHA-II or -I functional class and the incidence of restenosis decreased.


Subject(s)
Adult , Female , Humans , Male , Catheterization , Mitral Valve Stenosis , Cross-Sectional Studies , Disease-Free Survival , Hospitals, Special , Retrospective Studies , Time Factors
11.
Arch. Inst. Cardiol. Méx ; 70(4): 377-83, jul.-ago. 2000. ilus, graf
Article in Spanish | LILACS | ID: lil-280424

ABSTRACT

Presentamos los resultados obtenidos en 23 pacientes a los que se les colocaron 25 prótesis endovasculares (stent SAQ). Todos con enfermedad aterosclerosa coronaria y con diversas presentaciones clínicas como angina estable o inestable, infarto agudo del miocardio, como indicación primaria, y algunos casos de complicaciones postangioplastia coronaria con cualquiera de las patologías citadas. La mayoría de las lesiones eran complejas: obstrucciones totales, placas largas y enfermos en estado crítico. Los resultados inmediatos han sido satisfactorios ya que se logró mejoría angiográfica en todos los pacientes con respecto a la angioplastia convencional, con flujo TIMI 3 en 23 de las 25 lesiones tratadas y TIMI 2 en los dos restantes, en los que inicialmente fue TIMI 0. Se logró aumentar el diámetro arterial, comparado con el obtenido con la angioplastia convencional. Un enfermo presentó trombosis aguda, resuelta con nueva dilatación con balón, y en dos casos hubo protrusión de la placa aterosclerosa a través de las espirales del stent SAQ; en ambos, la obstrucción no fue significativa ni comprometió el flujo. Se tiene seguimiento clínico y pruebas de esfuerzo en todos los pacientes, realizadas en promedio tres meses después. A diez enfermos se les ha realizado angiografía coronaria, en cuatro por prueba de esfuerzo positiva, tres de ellos mostraron re-estenosis del SAQ, que se resolvió con dilatación con balón en forma exitosa, y otro se envió a tratamiento quirúrgico. En los seis enfermos restantes, se realizó la coronariografía por cumplir con el tiempo fijado por el protocolo; uno de ellos tiene dos stents, en ninguno encontramos re-estenosis.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty, Balloon, Coronary/methods , Blood Vessel Prosthesis , Coronary Artery Disease/therapy , Outcome Assessment, Health Care/methods , Exercise Test
12.
Arch. Inst. Cardiol. Méx ; 70(1): 38-45, ene.-feb. 2000. ilus, tab
Article in Spanish | LILACS | ID: lil-280390

ABSTRACT

La angioplastía coronaria transluminal percutánea con balón (ACTP) en las estenosis del tronco ha sido asociada con alta morbilidad para el procedimiento y pobres resultados a mediano plazo. Revisamos nuestra experiencia y evaluamos los resultados clínicos y angiográficos, así como el seguimiento inmediato de los pacientes con enfermedad del tronco coronario izquierdo (TCI), que fueron sometidos a tratamiento percutáneo con colocación de prótesis endovasculares (Stent).De febrero de 1995 a febrero de 1999 se realizaron 590 procedimientos con colocación de stent coronario en 468 pacientes, de los cuales sólo se incluyó un grupo selecto de diez sujetos con enfermedad del TCI. Éstos se consideraron inapropiados para cirugía de revascularización por malos lechos y por rechazo propio del enfermo a nueva cirugía. El éxito del procedimiento fue del 100 por ciento, sin casos de trombosis aguda, no hubo necesidad de cirugía urgente por complicaciones de la ACTP. En el seguimiento inmediato de tres a seis meses con control angiográfico, sólo ocurrió reestenosis en dos casos y no se reporta mortalidad secundaria al procedimiento. Conclusiones: la aplicación de stent en enfermedad de TCI protegido y no protegido puede ser seguro, y efectivo, como alternativa de cirugía de revascularización en un selecto grupo de pacientes con función ventricular conservada. Sin embargo, es muy importante tener un grupo mayor de población estudiada para conocer los resultados a mediano y largo plazo.


Subject(s)
Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary/methods , Coronary Artery Disease/therapy , Myocardial Ischemia/therapy , Coronary Disease/therapy , Cardiac Surgical Procedures/methods
13.
Arch. Inst. Cardiol. Méx ; 69(5): 445-53, sept.-oct. 1999. tab
Article in Spanish | LILACS | ID: lil-258857

ABSTRACT

Revisamos nuestra experiencia y evaluamos los resultados clínicos y angiográficos así como el seguimiento inmediato de los pacientes octogenarios que fueron sometidos a angioplastía coronaria transluminal percutánea con colocación de prótesis endovasculares (stents). En el periodo comprendido entre abril 1994 y septiembre de 1998 durante el cual se realizaron 532 procedimientos. Se incluyó a un grupo selecto de 51 pacientes (con 63 procedimientos con 1.23 stents por paciente) ya que estos rechazaron el tratamiento quirúrgico o se consideraron inapropiados para cirugía de revascularización, con edades de 71 a 85 años promedio de 74.09 ñ 3.1, con 37 hombres y 14 mujeres. De esto 64.7 por ciento con angina severa según la Asociación Canadiense de Cardiología (ACC). Con antecedente de infarto del miocardio previo el 52.9 por ciento y enfermedad multivascular 58.8 por ciento el porcentaje promedio de obstrucción arterial coronaria fue 90 ñ 9.2 y la fracción de expulsión 51.6 ñ 8.8. El éxito angiográfico inmediato fue 88.3 por ciento, (seis pacientes (12 por ciento) murieron durante 36 a 72 horas tras el procedimiento por diversas causas). El seguimiento fue de tres a 48 meses, pero sólo en 18 (35 por ciento) con control angiográfico, a siete (14 por ciento) se realizó prueba de esfuerzo en medicina nuclear por síntomas con resultado negativo, (14 (28 por ciento) enfermos foráneos no se efectuó seguimiento ya que no fue posible localizarlos y en cuatro (8 por ciento) con cambio de domicilio sin acudir a control posterior a esta unidad). Dos (4 por ciento) fallecieron por causas no cardiacas. Conclusiones: La aplicación de stents es un procedimiento exitoso angiográfico y clínico con bajo porcentaje de complicaciones. (Por tal motivo es una atractiva opción terapéutica en el manejo de la enfermedad arterial coronaria avanzada en este grupo frágil de pacientes)


Subject(s)
Humans , Male , Female , Aged , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary , Blood Vessel Prosthesis , Coronary Disease/diagnosis , Coronary Disease/therapy , Blood Vessel Prosthesis
14.
Arch. Inst. Cardiol. Méx ; 68(5): 370-6, sept.-oct. 1998. ilus
Article in Spanish | LILACS | ID: lil-227586

ABSTRACT

En la práctica de la angioplastía coronaria transluminal percutánea (ACTP), los problemas más importantes por resolver son la disección aguda, los resultados insatisfactorios y fundamentalmente el desarrollo de reestenosis; uno de los enfoques para resolver estas complicaciones ha sido el desarrollo de férulas endovasculares universalmente conocidas como stents (S). Esta tecnología es costosa para nuestro país, lo que estimuló el diseño y construcción de un S denominado SAQ que es motivo del estudio. Se presenta: La Metodología del desarrollo, fabricación y resultados in vitro y en vivo del SAQ; los resultados ex vivo, obtenidos en arterias coronarias de cerdo y en corazón humano; los resultados de dos modelos en animales: aorta de conejo y arterias periféricas en perro. En este trabajo se demuestra que el SAQ es seguro y efectivo, con propiedades generales semejantes a los existentes en el mercado


Subject(s)
Animals , Angioplasty, Balloon, Coronary , Arterial Occlusive Diseases , Coronary Angiography , Coronary Artery Disease , Prostheses and Implants , Prosthesis Design , Stents
15.
Rev. méd. IMSS ; 35(5): 341-5, sept.-oct. 1997. ilus
Article in Spanish | LILACS | ID: lil-226826

ABSTRACT

Reportamos dos pacientes a los que se les extrajo exitosamente, vía percutánea, un fragmento de catéter desde la vena cava superior, con la ayuda de un dispositivo diseñado por nosotros, a partir de un equipo de cateterismo cardiaco, como guía de Myler 8.0 french a la que se le cortó el extremo distal y se le introdujo una cuerda cubierta de teflón de 0.36 pulgadas, con la que se formó una asa, que se utilizó para atrapar el fragmento de catéter. Las ventajas del dispositivo son múltiples, destacamos que se puede fabricar inmediatamente y su costo es bajo, comparado con los dispositivos especiales. Se describen los pasos para diseñar el dispositivo, extraer el fragmento de catéter, así como sus indicadores, ventajas y desventajas


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Cardiac Catheterization , Foreign Bodies , Equipment Design/instrumentation , Equipment Design/methods
16.
Arch. Inst. Cardiol. Méx ; 67(3): 223-6, mayo-jun. 1997. ilus
Article in Spanish | LILACS | ID: lil-217301

ABSTRACT

Presentamos un caso de infarto agudo del miocardio del ventrículo derecho, secundario a oclusión posangioplastía del ramo ventricular de la arteria coronaria derecha, en que se desarrollarán cambios electrocardiográficos sugestivos de infarto anteroseptal, descartado por angiografía coronaria. Concluimos que el análisis cuidadoso de los cambios del segmento ST en las derivaciones V1-V4, puede orientar al diagnóstico de infarto del miocardio del ventrículo derecho. Por lo que recomendamos el registro rutinario de las derivaciones unipolares derechas del ECG (V3D, V4D), además de las izquierdas V7 y V8 que juntas conforman el "círculo torácico", en cualquier localización electrocardiográfica de infarto agudo del miocardio


Subject(s)
Humans , Male , Middle Aged , Electrocardiography , Myocardial Infarction/diagnosis , Heart Septum , Heart Ventricles
18.
Arch. med. res ; 27(2): 171-5, 1996. tab, ilus
Article in English | LILACS | ID: lil-200310

ABSTRACT

In order to establish the sentivity and specificity of tranesophageal strees echocardiography with dobutamine (TEE-dobutamine) in the early detection of myocardial ischemia we studied 30 consecutive patients from the Coronary Care Unit (CCU) of the Hospital de Cardiologia, Centro Medico Nacional Siglo XXI. The results were correlated with thallium 201-dipyridamole scintigraphy (TDS), and coronary angiography. Two groups were formed: Group I - 20 patients, 18 females/2 males, aged 37 - 73 years (mean 55 years) within the first week of myocardial infarction and/or unstable angina; Group II - 10 patients, five males/fives females, aged 35 - 65 years (mean 48 years) with atypical chest pain but with high suspicion of CHD. All group I patients, and none of group II, had significant stenoses on coronary angiography. Twenty patients had a positive TDS (18 patients from group I and two from group II). Twenty one patients had a positive test with TEE-dobutamine, 20 from group I and one from group II, which yields a sensitivity of 100 per cent, a specificity of 90 per cent, positive predictive value of 95 per cent and negative predictive value of 100 per cent


Subject(s)
Adolescent , Adult , Middle Aged , Humans , Male , Female , Coronary Angiography/methods , Dipyridamole , Dobutamine , Echocardiography , Echocardiography, Transesophageal/methods , Endoscopy, Gastrointestinal/psychology , Stress, Psychological/etiology , Myocardial Ischemia/diagnosis , Thallium
19.
Arch. Inst. Cardiol. Méx ; 63(4): 335-8, jul.-ago. 1993. tab
Article in Spanish | LILACS | ID: lil-177052

ABSTRACT

Desde marzo de 1986 hasta enero de 1993, se ha realizado comisurotomía mitral percutánea (CMP) en 91 pacientes con el diagóstico de estenosis mitral de etiología reumática. De éstos 2 cursaban con ambarazo de 30 (paciente 1) y 27 semanas (paciente 2) y estenosis mitral severa. Se realizó CMP con la técnica de Inoue, obteniendo incremento en el área valvular (0.8 a 1.6 y 0.7 a 1.9 cm²) y caída del gradiente transvalvular (19 a 4 y 12 a 0 mm Hg) inmediatamente después de la dilatación. En ambos casos, no se obtuvó comunicación interauricular (CIA) o insuficiencia mitral residual ni otras complicaciones. El tiempo de exposición a la radiación fue en promedio de 6.4 minutos de fluoroscopía y 6 segundos de angiografía. Con el fin de limitar la exposición a la radiación, se utilizó ecocardiografía Doppler color y se realizó protección radiológica del feto durante el procedimiento en ambos casos. En la paciente 1 se interrumpió el embarazo mediante cesárea a las 34 semanas por indicación obstétrica, y la paciente No. 2 tuvo parto por vía vaginal a las 37 semanas de embarazo sin complicaciones ni para la madre ni para el producto en ambos casos. Durante el seguimiento, el área valvular es de 1.7 y 2.1 cm², 15 y 4 meses después de la dilatación, respectivamente. Pensamos que la CMP con la técnica de Inoue es una excelente alternativa de tratamiento en pacientes embarazadas con estenosis mitral, lo que ofrece mejoría clínica inmediata sin los riesgos del tratamiento quirúrgico


Subject(s)
Humans , Female , Pregnancy , Adult , Catheterization/statistics & numerical data , Mitral Valve Stenosis/therapy , Fluoroscopy , Heparin/administration & dosage , Heart Failure/complications
SELECTION OF CITATIONS
SEARCH DETAIL